All 24 Terms

Term Definition
table units Fixed-diagnostic only; may have adjustable height Tilting-r&f rooms; may be described by tilting capabilities; fixed height to high for pt.
table top radiolucent; flat or curved top; smooth easily cleaned hard surface; motor driven or floating
table bucky tray holds cassettes; grid; phototiming equipment AEC
table ancillary equipment foot board; shoulder supports; handgrips; compression band
types of tube support overhead suspension; floor to ceiling; floor suspension; mobile; c-arm; head units; other-mammo, tomo, panoramic, CT, urologic
characteristics of overhead suspension two sets of ceiling mounted rails; most flexible; most expensive; telescoping column
incoming line current 110-120v @ 60 Hz
single phase power full wave rectification; 100% voltage ripple; 120 pulsations per sec.
three phase power incoming full-wave rectified current sequenced at 120 degrees; resulting in a six-pulse waveform; three phase, six pulse,;360 pulses per sec; voltage never drops to zero; three phase, twelve pulse
main x-ray circuit modifies the incoming power to the proper form to supply the x-ray tube
line compensator a meter for measure of voltage supplied to unit; control to precisely adjust voltage; automatic on newer radiographic units; in line before autotransformer
autotransformer supplied with 220v from primary circuit; taps used to alter kVp; voltage provided to autotransformer is the primary voltage; also provides voltage to filament transformer
kVp adjustment selects appropiate taps on the autotransformer; allows for selection of penetrating power of x-ray beam; pre-reading voltmeter
pre-reading voltmeter pre-reads voltage before voltage before it goes to high voltage transformer; part of kVp adjustment
special circuitry that will evalute the combination of mA, time, and/or kVp section for heat loading, and legal exposure limits
exposure switch anode must bea at correct speed before exposure is taken; exposure switch must be connected to the control console so that operator cannot be exposed (law); equipment is designed to prevent the tube from being manipulated into a position that will expose the operator, exposure switches must be of "dead man" type
dead man exposure switches finger has to be on switch to continue action
timer circuit in line on primary side of high voltage transformer
types of timer circuits mechanical; synchronous; pulse-counting; electronic
mechanical timer circuit rare, spring driven, inaccurate old
synchronous timer circuit timing related to frequency of electric current
pulse-counting timer circuit crystal oscillations at a determined frequency, would vibrate crystals at specific frequnces and the it would measure the # of vibrations
electronic resistor; length of exposure is determined by the time required to charge a capacitor through a selected variable resistance; time is varied by changing the resistance in the circuit; accurately measure times as short as 1ms
most widely used type of timer circuit electronic