Terms in this set (110)
A
stowage space
C
ship control sys
E
engineering control spaces
F
fuel/oil
G
gasoline tanks
J
JP-5 tanks
K
chemicals and dangerous materials
L
living spaces
M
ammo spaces
Q
misc spaces not covered by other letters
T
vertical access trunks
V
voids
W
water tanks
Compartment number 2-79-11-A
2- deck
79- frame (forwardmost frame of comp is 79)
11- relation to centerline (6th comp on starboard side 1,3,5,7,9,11)
A- compartment
x-ray
-set when in no danger of attack
- secured during x,y, and z
- eg. ship in anchor in well protected harbor
circle x-ray
-closed when condition x ray set
-may be opened without permission, but closed immediately
yoke
-maintained at sea during peacetime, and in port during wartime, and in port during peacetime outside of regular working hours
-secured during conditions yoke and zebra
circle yoke
-closed when yoke is set
-may be opened without permission but must be set immediately
zebra
-closed when condition zebra set
-once condition zebra is set, no closure (x,y,z) may be opened without permission of DCA
-set prior to leaving or entering port during wartime, also set immediately, without orders when manning general quarters stations
- set to isolate and control fires and flooding when the ship is not at GQ
Mod Zebra
-closed when an increase in watertight integrity is needed, not req to set entire ship set to condition zebra
-normally set on the DC deck and below (2nd deck)
-all main hatches closed, scuttles left to be open will be logged as such in DC Central
-eg. at restricted maneuvering in low visibility
circle zebra
-closed during condition zebra
-may be opened during prolonged periods of GQ with permission of the CO.
-opening of fittings allows evolutions like handing out rations, sanitary facilities, etc.
- must be guarded in the event the ship is req to rapidly reset condition zebra
dog zebra
-applies fittings opening to weather spaces that are not provided with darken ship switches or light traps
-closed from sunset to sunrise when underway
william
-kept opened during all material conditions of readiness
- applies to all vital sea suctions and vital valves
-secured only when necessary to control damage and CBR contamination
circle william
-normally kept open
-secured as defense against CBR attack and the spread of damage
DC emergency #
7211
When reporting, include the following info
- type of casualty
- degree of flooding, color smoke
-location of casualty by name, comp #, deck, frame, side of ship
simple fracture
occurs when broken bones doesnt break skin
compound fracture
when the bone breaks the skin and is exposed
treatment for electric shock
-secure power
- remove the victim from source
- begin CPR
first degree burn
-redness, increased warmth and mild pain
-immerse burn area in col water
second degree
-reddened and blistered
- severe pain
- soak in ice water
-apply sterile dressing
third degree
-destroys skin and destroy muscle tissue
-nerve endings destroyed
- treat for shock and give morphine
- use strile sheets to wrap victim
Stretcher: stokes
- most common
- consists tubular metal frame on which a shallow wire basket
stretcher: miller board
flat board made of plastic, yellow in color, with straps, also used in transporting injured personnel
CO2
-displaces oxygen
- non corrosive
- located 30ft from potential charlie fires
-must be grounded
AFFF
-aqueous film forming foam
- smothers fire by separating fuel from air
- 6 parts AFFF to 94 parts water
PKP
-potassium bicarbonate
-chemically interrupts chain reaction
-last resort for class charlie fires
What are two sizes of PKP?
18lb and 27lb
What are duration and ranges for PKP?
18lb- 10 seconds- 19ft
27lb- 11 seconds- 21 ft
Halon 1301
-chemically interrupts combustion chain
- minimum atmosphere concentration of 3% to be effective
-LSD-48 halon systems deliver 5-7% concentration
-space must be sealed for 15 min before reentry
-white smoke will appear when fire is out, black smoke if did not work
- installed in main engineering spaces, jp-5 pump room, paint, troop flam
APC
-aqueous potassium carbonate
-smothers deep fat fryer fire
- located in galley and wardroom
AFFF portable extinguisher
- bottle 28lbs, 55-65 sec, distance 15 ft
-charged to 100 psi
-one can extinguish 20 sq ft
Class A fire extinguishing method
water or AFFF
Class B fire extinguishing method
-halon 1301
- AFFF bilge sprinkling
- portable PKP
-water fog
-CO2
Class C fire extinguishing method
-secure power
-CO2
-water fog
-AFFF
-PKP last resort
Class D fire extinguishing method
jettison
methods of heat transfer
conduction
radiation
convection
positive ventilation
air forced in space
used to prevent spread of smoke
negative ventilation
air removed from space
buffer zone
established by closing hatches and doors adjacent to access of affected space
secondary boundaries
-set around buffer zone to check spread of smoke and provide safe area for personnel
-positive ventilation set within secondary boundary
Pressure Effects on the rate of flooding
an increase in depth results in an increase in pressure and increase in gallons per min
flooding boundaries
control flooding by securing all water tight fittings in the main water tight bulkheads and decks closest to flooding
soft patch
-emergency repair to low pressure piping
-rated 150 psi
jubbilee patch
-prefabricated metal band lined with rubber
- used to patch up to 100 psi
-fastest means of patching
banding kits
used to fasten sheet metal flange and gasket around a ruptured pipe
E.W.A.R.P
-Emergency Water Activated Repair Patch
- liquid activated resin repair kit
- used to patch pipes up to 150psi and 200 degrees
I-type shoring
strongest type
H-type shoring
subject to pressure acting perpendicular to axis
K-type shoring
most common type
Where is shoring materials located?
2nd deck in vicinity of repair lockers
CO2 extringuiusher specs
range: 4-6 ft
weight: 15lbs
continuous operation: 40 seconds
Portable AFFF extinguisher specs
-2.5 gallons of water at 10 psi
-one quart is AFFF concentrate
-produces 16 gallons expanded foam
-range: 15 ft
-duration: 55-65 seconds
Sizes of fire hoses
1.5 in or 2.5 in. Length 50 feet
AFFF in line eductor
injects 6% AFFF concentrate into 94% seawater
must be used with 1.5 in hose
one 5 gal tank of AFFF will last 60 seconds ad make 660 gallons of foam finish
Nozzle sizes and purpose
1 1/2 in used inside skin of ship
2 1/2 in nozzles can be used on weather decks
Types of eductors
S-type and peri-jet
How do eductors operate
firemain or p-100 pump
peri-jet
requires a 2 1/2 in and a 4 in discharge hose (2 for 1 ratio)
s-type
reqires a 1 1/2 in and a 2 in discharge hose (2 for 1)
electrical submersible pump
-used for de-watering compartmments that cannot be drained by installed drainage systems
-requires 2 1/2 in discharge hose
-can't be used to pump water with gas or heavy oils
-rated to deliver 140gpm against a max head of 70 ft or 200gpm at 50 ft static head
p-100 pumps
-4 on board
-rated 100gpm, 83 psig, w max 20 ft suction
PECU
-Portable Exothermic Cutting Unit
-used to cut holes on ships decks, bulkheads, and hatches
NFTI
-Naval firefighters thermal imager
-used to locate fire, scan hotspots, find casualties through smoke, find embers
Ram Fan (2000)
-driven by firemain and used in de-smoking
- uses a 1 1/2 in firehose for activation and discharge
-airflow 2000 ft per min
Primary function of fire main
to distribute seawater to fire fighting services and coutermeasure wash down sys
Secondary function of firemain sys
Provide water for flushing sys, air conditioning condensers, ship service air compressors, etc.
Type of Firemain
Double modified horizontal loop
Fire pumps
5 the feed the firemain system
Main Drainage System function
used for de-watering of main/aux/shaft alley. Used for normal drainage of MMR, AUX, shaft alley, waste water tanks, etc.
AFFF components
4 AFFF storage tanks (700 gallons each)
Halon bottles
Stores liquefied halon super pressurized with nitrogen to 600 psi at 70 degrees f.
Halon time delay
MMR 1, MMR2, AMR1, AMR2 = 60 sec delay
JP-5 pump rm, SD1, SD2, Troop flam, paint issue, paint mixing = 30 sec delay
Rage Guard Extinguishing System
deep fat fryer extinguisher
4 types of nuclear radiation
ALPHA: large in size, short range, stopped by thin paper
BETA: stopped by clothing, short range
GAMMA: internal body damage, long range, can penetrate all matter
Neutrons: long range, hazardous
base surge
cloud of radioactive mist caused by subsurfacenuclear explosion
shock wave
over-pressurization in the air or water caused by a nuclear explosion
roentgen
unit of measurement used for gamma radiaiton
radiac
portable instrument used to measure radiation intensity
dosimeter
portable device which measures the total amount of radiation recieved
MCU-2P
mask used during biological attack
decontamination
physical removal through use of water and calcium hypochlorite solution
M-291
skin decontamination kit
M-8 paper
detects V, G, and liquid nerve agents
What does MOPP stand for? What is it used for?
Mission oriented protective posture. CBR defense. Incremental increase in personnel protection
MOPP level 1
SUSPECTED THREAT
-masks fitted for immediate use
- consist of mask, chem protective glove set, decontamination kit, atropine injectors, 2-Pam chloride injectors, tablets
MOPP level 2
POSSIBLE THREAT
protective mask is in carrier and worn on person
MOPP level 3
PROBABLE THREAT
-maintain mask on persons
- all weather ddeck activites require donning wet weather gear over ppe
MOPP level 4
IMMINENT THREAT
- don protective mask
- don chemical protective glove set
-don battle dress
Repair Party Leader
responsible for organization and training of the personnel assigned to his/her repair locker
Fire Marshall
proceeds directly to scene to direct efforts of rapid response team. if capabilities beyond RRT, turn over with on scene leader
On Scene Leader
-in charge at scene
- shall wear SCBA and flash hood and gloves
- determines where to establish initial fire and smoke boundaries
Team Leader
-Will wear SCBA
- Carries NIFTI
- directs nozzlemen
- attack team leader is required when two hoses are employed within the same compartment
Investigators
Follows principles of investigation (rapid but cautious, thorough, report all findings, repeats investigation)
- wears OBA
works in pairs
Boundaryman
-proceeds directly to the scene whenn casualty called away
-cools bulkheads
removes flammable material
Messenger
relays orders and info
uses phraseology, message blanks, DC symbology
Accessman
gains access to the casualty-affected space when directed by OSL. Must be familiar with forcible entry equipment (PECU)
Rapid Response Team
-proceeds directly to scene
- No SCBA or protective clothing required
- minimum of 4 personnel will be assigned
Attack Team
-team leader
- #1 nozzlemen
- #1 hoseman
- #2 nozzleman
- #2 hosman
What is CPS? What does it stand for?
Collective Protection System
;