Home
Browse
Create
Search
Log in
Sign up
Upgrade to remove ads
Only $2.99/month
SOGs
STUDY
Flashcards
Learn
Write
Spell
Test
PLAY
Match
Gravity
Terms in this set (230)
The _______ _______ _______ _______ Will be the manager and focal point for processing all matters relating to the S0Gs. [1001]
Assistant chief of operations
Serving with pride and professionalism. [1001]
Town of Davie fire rescue motto
The standard operating guidelines committee shall convene _______ at a minimum. [1002]
annually
_______ _______ are required to maintain the SOG binder, adding and/or replacing SOG documents as directed by the Fire Chief. [1002]
Station officers
Requests deemed to directly affect the _______ of department personnel can be developed, implemented or revised by the department in lieu of a scheduled committee meeting. [1002]
Safety
_______ _______ or revised SOG's necessitated by product changes, equipment changes, staffing changes, or vendor changes may be implemented in lieu of a scheduled committee meeting. [1002]
Newly developed
New or updated SOG documents will be posted on the intranet. Company and chief officers will review new and updated SOG documents with their personnel prior to the implementation date. ( _______ _______ from posting). [1002]
10 days
The effective date of the SOG shall be no later than _______ _______ after adoption. [1002]
30 days
The body of an SOG show always begin with the _______ , and include any disclaimer for deviation should any be allowed. [1002]
Purpose
A building shall be considered to be occupied at anytime it needs any of the following criteria: It is open for general occupancy, It is open to the public, It is occupied by more than _______ persons. [1003/Definitions]
10
Other potentially infectious material. [1003/Definitions]
OPIM
Contains 115 feet of 1/2 inch CMC static pro life line with two stainless steel loops. [1003/Definitions]
Fall arrest rope bag
Scott electronic management system portable unit. [1003/Definitions]
SEMS-PU
Scott electronic management system base unit. [1003/Definitions]
SEMS-BU
The gray button located on the upper portion of the left side of the SEMS-PU/SCBA. [1003/Definitions]
Withdraw/critical event button
Staging that occurs automatically during the initial stages of an incident unless directed otherwise by the IC. [1003/Definitions]
Level I staging
A more formalized and organized staging procedure. During _______ _______ _______ , a formal staging area is designated. A staging officer is assigned and units are directed to the staging area.
Level II staging
THREAT - In acronym from the Hartford Consensus highlighting the importance of initial actions to control hemorrhaging.
(T)hreat suppression
(H)emorrhage control
(R)apid (E)xtrication
(A)ssessment
(T)ransport
ASHE
Acronym for:
(A)ctive
(S)hooter
(H)ostile
(E)nvironment
Request for chief fire officer notification only. [1101/Chief Call Out]
Group 2 page
Request for chief fire officer response.
[1101/Chief Call Out]
Group 3 page
If the request is to de-energize the area the FPL dispatcher will advise the blackout may effect up to _______ _______ _______ including traffic signals, any hospitals, elevators or railroad crossings. [1102/Electrical]
1 square mile
The activation of an alarm due to mechanical failure, malfunction, improper installation for the negligence of the alarm user, or his agents and employees, or any alarm company associated with the maintaining, releasing, or generating responses to an alarm. [1103/Fire alarms]
False alarm
T/F By SOG, false alarms include alarms caused by hurricanes, tornadoes, lightning, or other circumstances determined by the enforcement officer to be beyond the control of the user. [1103/Fire alarms]
False
False alarms in an unoccupied structure. In the absence of any evidence of fire conditions, units will clear scene after anyone of the following: (4)
[1103/Fire alarms]
1) Completion of a reasonable investigation
2) Confirmation by the alarm company of fire alarm
reset
3) Expiration of 30 minutes waiting period
4) The call-out representative is contacted and
refuses to respond
In an unoccupied structure with fire alarm, what conditions will require entry into the occupancy? [1103/Fire alarms]
An active water-flow alarm with evidence that water is flowing
Only when there is a clearly identifiable "_______ _______", fire personnel will make an attempt to reset a fire alarm system. NOTE: No other method of resetting the alarm will be considered. [1103/Fire alarms]
Reset button
When a fire alarm system in an occupied building cannot be reset, the company officer will notify the property manager they will have _______ _______ to make repairs to the fire alarm. [1103/Fire alarms]
4 hours
Where a required fire alarm system is out of service for more than _______ _______ _______ _______ _______ _______ _______ , the AHJ shall be notified and the structure shall be evacuated or an approved fire watch shall be provided for all parties left unprotected by the shutdown. [1103/Fire alarms]
4 hours in a 24 hour period
A CAN report is a quick progress report that relays vital information between the IC and working companies during all phases of operations on a fire ground incident. [1104/Fireground]
Conditions
Actions
Needs
The complete and accurate gathering of information is crucial for the development of incident objectives, goals, strategy and tactics. Size up is conducted in three phases: [1104/Fireground]
Receipt of alarm
Upon arrival
Ongoing
The first arriving fire rescue unit initiates the command process by giving an initial radio report. This should include: (8) [1104/Fireground]
1) Unit designation
2) Description of the situation
3) Announcement of "working fire" if applicable
4) State: Will hold with, Investigating, False alarm
5) Declaration of command location and strategy
(Offense of strategy is assumed)
6) CAN report
7) Any safety concerns or hazards
8) Additional resources
First arriving engine should position in a fashion to facilitate hose line deployment and advancement, _______ _______ _______ , and operating top mounted master streams. [1104/Fireground]
Supplying a FDC
Per the SOGs, there are two principal modes of operation that DFR will employ, _______ and _______ . [1104/Fireground]
Offensive, defensive
The three tactical priorities, and the IC radio announcements associated with each are as follows: [1104/Fireground]
Rescue (all clear)
Fire control (fire under control)
Property conservation (fire out, loss stopped)
When a _______ strategy is initially taken, it should be announced that a primary search will not be conducted. [1104/Fireground]
Defensive
Fire control involves three phases: _______ , _______ , and _______ . [1104/Fireground]
Locating, confining, and extinguishing
When water is limited, _______ _______ maybe the best alternative. [1104/Fireground]
Exposure protection
1 3/4" = 150 GPMs
2 1/2" = 250-350 GPMs
Master stream = 350 GPMs
[1104/Fireground]
Hoselines, handlines, streams per GPMs
Prior to releasing the property back to the occupant, metered carbon monoxide reading should less than _______ ppm. [1104/Fireground]
9
For vertical ventilation, generally a minimum of a _______ x _______ opening for residential structures, and a minimum of an _______ x _______ openings for other structures are recommended. [1104/Fireground]
4 x 4, 8 x 8
Five metal gates staggered along the barrier wall of the I-595 express lanes. 1, 3 and 5 can be accessed from west bound I-595 general-purpose lanes. 2 and 4 can be accessed from the east bound I-595 general-purpose lanes. [1105/Highway]
Emergency access gate (EAG)
10 paved entry egress points along the grass median between general-purpose lanes and the express lanes on I-75. [1105/Highway]
Emergency access crossover (EAC)
Three reversible express toll lanes, serving express traffic to and from I-75. [1105/Highway]
I-595 express lanes
Five Geographic zones identified by the following colors: (5 colors) [1105/Highway]
I-595 response zones
Red, yellow, green, orange, and white
FSS (I-595). [1105/Highway]
Fire suppression system
FDCO
FDCI (I-595). [1105/Highway]
Fire department connection outlets
Fire department connection inlets
There are _______ strategically located fire department connection inlets. _______ FDCI is located on westbound State Road 84 (Alpha) and _______ are located on Reese Road. (Sierra/Tango) [1105/Highway]
17, 1, 2 (westbound, west of 136)
There are _______ fire department connection outlets staggered along the divider walls of the I-595 express lanes. [1105/Highway]
55
TMC [1105/Highway]
Traffic management center
If it is decided to close the highway notify _______ . [1105/Highway]
TMC
I-595 Express Lanes, Weekdays
_______ to _______ Eastbound travel
_______ to _______ Closed for maintenance
_______ to _______ Westbound travel
_______ to _______ Closed for maintenance
I-595 Express Lanes, Weekends
_______ to _______ Eastbound travel
[1105/Highway]
0400, 1300
1300, 1400
1400, 0200
0200, 0400
0400 Saturday, 1300 Monday
Highway incident response assignments:
Accident with injuries:
[1105/Highway]
Engine (2)
Rescue (1)
Highway incident response assignments:
Single vehicle fire:
[1105/Highway]
Engine (2)
Highway incident response assignments:
Trucks larger than pick ups and vans including motorhomes:
[1105/Highway]
First alarm:
Engines (2)
Rescue (1)
Battalion chief (1)
On highway incidents, it is the responsibility of the primary engine company officer to provide _______ _______ _______ _______ _______ . [1105/Highway]
Specific directions regarding approach and direction for other responding units
Special considerations for a compromised tanker on highway: [1105/Highway]
Hazmat, liquid transfer equipment (Cliff Berry, etc.)
Location of emergency access gates, eastbound: [1105/Highway]
EAG 2: SW 104th Ave (Flamingo)
EAG 4: SW 75th AveHeyHear (Nob Hill)
Location of emergency access gates, westbound: [1105/Highway]
EAG 1: SW 124th Ave (Pine Island)
EAG 3: SW 97th Ave (University, wrong. Davie Rd, correct)
EAG 5: SW 77th Ave (Davie Rd)
Nothing specific to highlight. [1106/Lobby]
Nothing specific to highlight.
A situation that grows at a rate faster than the response rate to that situation. [1107/Additional Resources]
Reactive incident management
Who shall ensure that the alarm paperwork is completed on every false alarm incident? [1108/False Alarms]
Company officer
(BC follows up on Company officer)
(Assistant chief of operations follows up on BC and ensures paperwork is forwarded to fire and life safety)
Third false alarm within fiscal year, refer to town ordinance section 16-5. Cost for residential and occurrence _______ , $ _______ . Cost for commercial and occurrence _______ , $ _______ . [1108/False Alarms]
3rd, $100 (and each subsequent)
3rd, $250 (and each subsequent)
Forms required for tracking a false alarm. [1108/False Alarms]
Alarm response notification
Alarm report
Code of ordinances town of Davie
False alarm invoice
Two methods to reactivate the traffic preemption device. [1109/Traffic preemptive device]
1) Depress the on/off button
2) Shut your emergency lights off and then turn them back on
When should the driver of any apparatus confirm that the traffic preemption device is functioning correctly? [1109/Traffic preemptive device]
Every morning check out
What are the four steps in checking the traffic preemptive device? [1109/Traffic preemptive device]
1) Turn on all warning lights
2) Preemption device will turn on
3) Green lights on the unit will indicate system is operational
4) Open the driver's door to cancel the preemption device
When the vehicle engine is started, the Ward diesel diverter is activated for _______ seconds. [1110/Ward Diesel]
25
When the Ward diesel light is to the point of on or solid all the time, then the system will start and the light will light for _______ seconds, the filter system will detect a clogged filter And shut off the filter system. [1110/Ward Diesel]
10
The ceramic filter will require servicing but it will not down the unit from active service. The Ward diesel filter system will stay in the "on" position at ALL TIMES. [1110/Ward Diesel]
Important information regarding Ward diesel filter system
The ASAP fall arrester is rated for a maximum weight of _______ kg. (________ lbs.) [1201/Fall Arrest]
140, 308
Nothing specific to highlight. [1202/Lock Out]
Nothing specific to highlight
The pet oxygen mask kits will be located on the Italian vehicle. Set appropriate 02 flow rate: [1203/Pets]
Small 1-3 LPM
Medium 3-5 LPM
Large 5-7 LPM
When using ByoPlanet, appropriate PPE chemical protection shall be used at all times. A minimum of an _______ _______ , _______ _______ _______ _______ , with maximum ventilation to the area. [1204/ByoPlanet]
N95 mask, gloves and eye protection
As a general rule, the ByoPlanet application rate is _______ minute of spray per _______ ft.² for use. [1204/ByoPlanet]
1, 500
At a minimum, monthly decontamination and disinfection with the use of the ByoPlanet of engine and rescue units will occur _______ _______ _______ _______ of the _______ App. [1204/ByoPlanet]
During the first week of the month
Routine disinfection of stations will occur at least _______ - _______ during station rotation or after any suspected contamination of blood or OPIM. [1204/ByoPlanet]
Semi-annually
Always carry a power saw ______ _______ _______ _______ . The blade should be carry to the front with muffler away from your body. [1205/Power Saws]
With the engine stopped
Have a plan of action before placing the salt into operation. The plan should include: [1205/Power Saws]
Location and sequence of cuts
Wind direction
Escape routes, Two means of egress
A member who operates a power saw for the purpose of daily inspection or maintenance shall wear _______ , _______ _______ , _______ _______ , _______ and _______ _______ . [1205/Power Saws]
Helmet, bunker coat, fire gloves, ear and eye protection
_______ has the responsibility for preventative maintenance and to change the chains and spark plugs. [1205/Power Saws]
FVS
The SEMS-PU will automatically power on when the air cylinder is open and the unit is charged with at least _______ psi. [1206/SEMS]
80
The amber flashing range icon displayed in the status window indicates to the end-user that the _______ is searching for the _______ . [1206/SEMS]
SEMS-PU, SEMS-BU
The _______ _______ - _______ range icon displayed in the status window indicates that the SEMS-PU has located a SEMS-BU and is waiting to be logged in. [1206/SEMS]
Green non-flashing
At approximately _______ psi, a warning is transmitted audibly as a short distinct two-tone alarm that it sounded four times. [1206/SEMS]
2250
At approximately _______ psi, a warning is transmitted audibly as a short distinct two-tone alarm that is sounded indefinitely. [1206/SEMS]
1125
In addition to a low air audible alarm, the regulator will vibrate once the low air alarm activates and will continue to vibrate until there is approximately _______ psi or less. [1206/SEMS]
100
If the PASS device unit has not detected any movement for a period of _______ seconds, it will emit a pre-alert audible alarm and visual alarm as indicated by the four LEDs flashing sequentially two up and two down on theSEMS-PU. [1206/SEMS]
20
The audible alarm on a PASS device, after the pre-alert audible alarm has been activated, will escalate in volume for _______ seconds and then go into full audible alarm. [1206/SEMS]
10, (full alarm at 30)
After a period of _______ seconds in full alarm, the SEMS-PU will transmit a distressed alarm to the SEMS-BU. [1206/SEMS]
10
To manually activate the SEMS-PU PASS/Firefighter down alarm, depress and hold the _______ button, located top center of the face of the SEMS-PU for _______ _ _______ seconds. [1206/SEMS]
Red, 2-3
Manual activation of the PASS device will only be appropriate _______ _______ _______ _______ to the _______ . [1206/SEMS]
After making radio contact to the IC
In the event of an evacuation transmission from the SEMS-BU, personnel operating on scene will receive _______ _______ _______ _______ ______ ________ _______ . Each set will consist of three electronic air horn blasts from the air pack. [1206/SEMS].
Four sets of a distinctive sounding alarm
In the event of an evacuation, distinctive electronic air horn blasts will continue to activate every _______ seconds until the end user depresses the yellow button twice. This will increase the delay between the cycles of alarms to _______ seconds. [1206/SEMS]
10, 60
If the end-users pass alarm pre-alert activates due to non-movement, the delay on the evacuation alarm blasts will default back to every _______ seconds. [1206/SEMS]
10
All personnel wearing work uniforms will wear hand-held radios in one of the following approved methods: [1207/Radio Security]
Wear belt, belt attachment and leather holster
Wear belt and use radio clip
Wear shoulder strap and leather holster
The SupraSafe key is to be carried by the Battalion Chief, Captain, Lieut./crew leader and Fire & Life Safety division personnel at all times. It is to be passed on to the oncoming officer at shift change. [1208/Supra Key]
Do not attach the supra key to the Officer's handle in the engine.
A log sheet of all the SupraSafe keys will be kept by the _______ _______ _______ _______ . [1208/Supra Key]
Fire & Life Safety division
The IC will announce "Emergency Traffic" and have Fire Com sound the radio alert tone, and state, "All personnel evacuate the building or area immediately." This shall be repeated _______ . [1301/Emergency Evac]
Twice
When the order to evacuate is given, all on scene available and appropriately equipped units in the immediate vicinity will blow airhorns intermittently (one second on, one second off) for _______ _______ . [1301/Emergency Evac]
30 seconds
The _______ _______ is the area between the fire and the engine being utilized as a decontamination area. The _______ _______ is the location the decontamination will occur. The _______ _______ is near the IC and rehab area. [1302/Firefighter Decon]
Hot zone, warm zone, cold zone
The driver engineer assigned to decontamination shall wear at a minimum, _______ , _______ , _______ . [1302/Firefighter Decon]
Trauma sleeves, gloves, and N95 mask
The decon area should be near an available engine with a stretched low flow line _______ - _______ feet away from the engine to avoid vehicle exhaust. [1302/Firefighter Decon]
25-50
Goals of Rehab (6 R's): [1303/Firefighter Rehab]
Rest
Rehydration
Restoration
Rx
Relief
Refueling
During rehab, all supervisors shall maintain an awareness of the condition of each member operating within their span of control. [1303/Firefighter Rehab]
Company officers
Climatic or environmental conditions that do indicate the need to establish rehab include a heat stress index above _______ °F or a wind chill index below _______ °F. [1303/Firefighter Rehab]
90, 10
Personnel entering rehabilitation for the first time shall rest for a minimum of _______ _______ and longer where practical. [1303/Firefighter Rehab]
10 minutes
Personnel shall rest for a minimum of _______ _______ following the use of a second SCBA cylinder, or _______ _______ of intense work without SCBA. [1303/Firefighter Rehab]
20 minutes, 40 minutes
After the _______ _______ of an incident, sports drinks containing electrolytes should be made available. Alternate drinking water and Gatorade. [1303/Firefighter Rehab]
First hour
Sports drinks should not be _______ and carbonated beverages should also be _______ . [1303/Firefighter Rehab]
Diluted, avoided
The IC should consider furnishing foods when emergency incidents extend longer than _______ hours. [1303/Firefighter Rehab]
3
The rehab officer shall secure all necessary resources required to adequately staff and supply the rehab area. [1303/Firefighter Rehab]
Rehydration fluids
Food
Medical equipment and supplies
Special support equipment
Paperwork
_______ - _______ ºF : Extreme caution, Heat cramps
_______ - _______ ºF : Danger, Heat exhaustion
_______ - _______ ºF : Extreme danger, Heat stroke
[1303/Firefighter Rehab]
90 - 105
105 - 130
Above 130
T/F The term "Emergency Traffic" will be used prior to a "Mayday" [1304/Trapped Firefighter]
F
The lost or trapped firefighter must activate _______ _______ _______ _______ on the portable radio. [1304/Trapped Firefighter]
The emergency traffic button
Lost firefighters should give command information as to who they are, how many firefighters, Branch/Division/Group/Unit they were operating in, where they think they are, description of building structures surrounding them, sounds of nearby activities, or any other information that might direct rescue crews to their location. [1304/Trapped Firefighter]
Not LUNAR (per SOG's)
Location
Unit
Name
Air
Resources
Call for help immediately
Activate portable radio emergency button
Mayday
LUNAR (but not per SOG's)
Advise on info or main
Activate PASS device
Crews stay together
Follow the hose or lifeline out
Search for an exit
Retreat to a safe refuge
Stay calm and conserve air
Get in a horizontal position
Flashlights or tapping noise
[1304/Trapped Firefighter]
Basic guidelines for firefighters to follow if they become lost, trapped or separated from their crew in a building
Company officers who are unable to locate a crew or firefighter assigned to them must immediately notify command and use _______ . [1304/Trapped Firefighter]
Mayday
PAR [1305/PAR]
Personnel accountability report
The company officer will _______ _______ _______ _______ with an intact crew anytime a radio failure occurs. [1305/PAR]
Exit the hazard zone
Discrepancy: If a radio fails while in the Hazard zone, the crew will _______ ______ _______ _______ _______ . [1305/PAR]
Exit unless there is another working radio with the crew
The accountability officer maybe a _______ , _______ _______ , or a designated _______ _______ depending on the nature, type and complexity of the incident. [1305/PAR]
Driver, Branch/Division/Group Officer, FiveAccounting Officer
Report of a missing or trapped firefighter
Change from offensive to defensive operations
Sudden hazardous event
Report of an "all clear"
At each 30 minute interval of elapsed incident time
Report of "fire under control"
[1305/PAR]
Par will be required for the following situations:
1) Any incident requiring entry into a hazard zone
2) Any incident that requires the use of SCBA
3) For single company incidents with passport will remain on the apparatus dash
4) For multi company operations where SCBA is used
5) Second alarm or greater responses
[1305/PAR]
Passport implementation
For any reports of missing firefighters, command must _______ _______ _______ _______ _______ . [1305/PAR]
Request the next greater alarm assignment
Brush fire assignment: [1401/Brush fire]
Single engine, code 3
**
If structure impingement is reported or suspected, multi-company response
**
Consider Class A foam for thick vegetation areas at _______ - _______ % concentrate. [1401/Brush fire]
.25-1
In _______ _______ _______ , the second and third arriving units take up a position about one block away. [1402/Commercial]
Level 1 staging
In Level 2 staging, a more formalized, organized staging is designated. A _______ _______ _______ _______ and units are directed to the staging area. (may be several blocks from the incident) [1402/Commercial]
Staging officer is assigned
Commercial fire assignment: [1402/Commercial]
Multi-company, Code 3
1) Establish incident command and indicate operational mode (Investigation, quick attack, defensive)
2) Size up with 360º
3) Declare "working fire" if indicated
4) Secure a water source
5) Solicit relevant information
6) Initiate PAR
7) Check alarm panel
8) Deploy initial fire stream
9) Update fire attack progress
10) Assist with search/rescue, ventilation, salvage/overhaul
11) Assist owners/tenants
12) Determine cause/source
[1402/Commercial]
First arriving engine company responsibilities on a commercial structure fire
First arriving rescue unit responsibilities on a commercial structure fire (Evacuated victims)
Discrepancy: Second arriving engine company responsibilities on a commercial structure fire (Secure a water source, Supply standpipe/sprinkler system)
Compactor fire assignment: [1403/Compactor]
Multi company, battalion chief, code 3
1) Establish incident command and indicate operational mode (Investigation, quick attack, defensive)
2) Size up with 360º
3) Declare "working fire" if indicated
4) Secure a water source
5) Solicit relevant information
6) Initiate PAR
7) Determine if evacuation is needed
8) Deploy initial fire stream
9) Update fire attack progress
10) Assist owners/tenants
11) Determine cause/source
[1403/Compactor]
First arriving engine responsibilities on a compactor fire
First arriving rescue unit responsibilities (Perform forcible entry where needed)
Special considerations for a compactor fire. [1403/Compactor]
• Consider Class A Foam
• Assure that fire has not spread into building via chutes or utility pathways
Dumpster fire assignment: [1404/Dumpster]
Single engine, code 3
**
If structure impingement is reported or suspected, multi-company response
**
1) Initial size up
2) Request additional resources as needed
3) Establish IC
4) Complete size up
5) Proper engine placement
6) Begin fire attack (Class A Foam if necessary)
7) Overhaul
8) Determine cause and origin
[1404/Dumpster]
First arriving engine responsibilities on a dumpster fire
Special considerations for a dumpster fire: [1404/Dumpster]
• Chutes that lead to dumpster may transfer fire
• Hazmat
Educational complex fire assignment: [1406/School]
Multi company, battalion chief, code 3
1) Establish IC
2) Size up with 360º
3) Declare "working fire" if indicated
4) Secure a water source
5) Solicit relevant information
6) Initiate PAR
7) Recon fire area
8) Update incoming BC and transfer command
9) Initiate rescue, fire attack, ventilation and salvage/overhaul
10) Assist with recovery
11) Determine cause/source
[1406/School]
First arriving engine responsibilities on an educational complex fire
First arriving rescue unit responsibilities on an educational complex fire (Evacuated victims)
Special considerations for an educational complex fire: [1406/School]
• Confine
• Attack from unburned side
• Protect egress
• Multiple radio channels
• Students and staff accountability
For purposes of this guideline, _______ _______ - _______ shall be defined as a structure where the firefighting attack lines cannot reach the fire via normal pre-connected lines, or via hoisting up to external balconies. [1407/High-rise]
A high-rise
SOG does not state assignment for [1407/High-rise]
[1407/High-rise]
All crews arriving at incidents involving _______ _______ , _______ _______ , _______ _______ _______ _______ at high-rise buildings must assume that an active concealed fire is present until ruled out by DFRD personnel. [1407/High-rise]
Fire alarms, smoke boaters, and reports of fire
In most high-rise situations the need for establishing _______ _______ the structure is secondary in urgency to the need to get an _______ _______ _______ up to the fire floor. [1407/High-rise]
Command outside, Officer and crew
On an active high-rise fire, a hazard zone shall be established _______ _______ around the building.
[1407/High-rise]
200 feet
On an active high-rise fire, all personnel shall remain at least _______ _______ away from the hose lines supplying the FDC. [1407/High-rise]
50 feet
A _______ _______ _______ should be assigned as quickly as possible to the firefighting level of a confirmed high-rise fire. Division XX (XX=Fire floor). [1407/High-rise]
Chief fire officer
1) Obtain keys from the building's supra box
2) Maintain elevator control
3) Locate alarm annunciator panel
4) Shut off alarm system once command has determined that building is evacuated
5) Identify which stairwells can be used
6) Control the building's emergency phone
7) Evacuate remaining occupants
8) Prevent occupants from reentering
9) PAR and passport accountability
10) Liaison with maintenance and security personnel
11) Additional resources to lobby control if needed
[1407/High-rise]
Establishing lobby control and lobby control duties
1) Accurately determine the location of the fire
2) If fire detectors are activated on several floors, always assume that the lowest floor is the start of the problem
3) Firefighters shall NEVER take the elevator to the actual floor of the incident. Always take the elevator two floors below and walk the rest of the way.
4) Prior to entering the elevator car look up the hoistway For water or smoke entering the hoistway which voids the use of that particular elevator
5) All firefighters entering elevators must be fully bunkered out, have the SCBA tank turned on and be prepared to immediately don the facepiece
[1407/High-rise]
Upper floor access and procedures (Elevator use)
In a high-rise fire, At least _______ _______ should proceed to the fire area. Companies shall set up for operation on the floor below the incident. [1407/High-rise]
Two companies (Engine and rescue)
In a high-rise fire, Firefighting hose lines shall not be connected to standpipes on the _______ _______ _______ , or _______ the incident. [1407/High-rise]
Same floor as, Above
In a high-rise fire, Fire officers should seriously consider the deployment of a _______ _______ prior to fire attack if the fire has already extended into an interior hallway. [1407/High-rise]
Backup line
Personnel assigned to stairwell support should station themselves on _______ _______ floor. These personnel should not have to travel more than _______ flights each. [1407/High-rise]
Every other, Two
An area established two floors below the fire floor. This area shall be used to stage extra SCBA bottles and equipment, rehab firefighters, medically evaluate firefighters, and possibly triage victims.
Base staging area
RIC should be deployed to the _______ of the floor immediately below the fire floor. [1407/High-rise]
Stairwell
The first arriving engine officer on a high-rise fire should equip themselves with: [1407/High-rise]
Hand light, elevator keys, utility line, thermal imager
The first arriving ladder officer on a high-rise fire should equip themselves with: [1407/High-rise]
Hand light, elevator keys, irons, thermal imager
The second arriving engine officer on a high-rise fire should equip themselves with: [1407/High-rise]
Hand light, elevator keys, spare SCBA bottle, thermal imager
The third arriving engine officer on a high-rise fire should equip themselves with: [1407/High-rise]
Hand light, elevator keys, search rope, thermal imager
The company officer performs a size up (_______ _______ , _______ _______ from exposures, electrical, gases, traffic, crowd control) and gives the order for the appropriate attack line. [1408/Vehicle fires]
Stabilize vehicle, protect crew
In addition to a hand line, place a _______ _______ _______ _______ between the apparatus and the incident. This will allow a firefighter to extinguish a flammable liquid fire spill. [1408/Vehicle fires]
20 lbs. dry chemical extinguisher
Commercial vehicle fire assignment:
[1409/Commercial Vehicle fires]
Engine, rescue, code 3
Size up
Park uphill, upwind if practical
Shield crew from traffic with apparatus
Identify placard
Determine if occupants are safe
Request hazmat if needed
Secure water source
Deploy attack line
Overhaul
Determine cause/source
[1409/Commercial Vehicle fires]
First arriving engine company responsibilities
Class B foam at 3% to 6% concentrate
Fuel tank rupture
Hazardous cargo
Special considerations
Driver engineer SOG's [1501/Drafting]
[1501/Drafting]
On a reverse hose lay the driver operator does not exceed _______ _______ . [1503/Reverse lay]
10 mph
On a forward hose lay the driver operator does not exceed _______ _______ . [1502/Forward lay]
10 mph
The captain will input the gallons of non-metered potable water used in the water use information field in FireRMS: suppression functions under water use field in the _______ _______ . [1504/Non-metered water]
Apparatus tab
The captain will input the gallons of non-metered potable water used in the water use information field in FireRMS: training functions under water use field in the _______ _______ . [1504/Non-metered water]
Definition tab
The captain will input the gallons of non-metered potable water used in the water use information field in FireRMS: other functions under water use field in the _______ _______ . [1504/Non-metered water]
Definition tab
Hose testing:
13 gallons for each 100 feet of 1.75 inch of hose
26 gallons for each 100 feet of 2.5 inch of hose
40 gallons for each 100 feet of 3 inch of hose
100 gallons for each 100 feet of 5 inch of hose
[1504/Non-metered water]
Water usage per hoseline
Blue- 1500 GPMs
Green- 1000 to 1499 GPMs
Orange- 500 to 999 GPMs
Red- 499 and under GPMs
[1504/Non-metered water]
Hydrant tops/colors:
Driver engineer SOG's [1505/Hand lines, GPMs]
[1505/Hand lines, GPMs]
Driver engineer SOG's [1506/Relay pumping]
[1506/Relay pumping]
The _______ arriving engine has the responsibility to supplement the standpipe/sprinkler system with additional water flow and increase water pressure.[1507/Standpipe]
Second (per [1507/Standpipe])
Air plane crash has already occurred. [1601/Aircraft]
Alert 3
Passengers and crew on board. [1601/Aircraft]
Souls
Aircraft emergencies assignment: [1601/Aircraft]
Multi company, crash truck, code 3
Information to be obtained from CAD or FireCom: [1601/Aircraft]
Location
Approach we're taking off
Type of aircraft
Size of aircraft
Passenger or cargo
Souls on board
Wind speed and direction
First arriving engine's responsibilities on an aircraft emergency. [1601/Aircraft]
Established command
Water source
Foam line
Stabilize aircraft
Use of crash truck
May need class D extinguishers
Broward County warning point
Notify FAA, NTSB
Jet fuel burns hotter 800 to 1500°F, (not listed on SOG)
[1601/Aircraft]
Special considerations for an aircraft emergency
Bomb emergency response assignments: [1602/Bomb]
Full, battalion chief, code 1
Size up
Consider terrorist activity
Obtain information from PD
Consider evacuation areas (500 feet or greater)
Initiate PAR
Update incoming BC
Stage until deployed or released by PD
[1602/Bomb]
First arriving engine responsibilities for a bomb emergency
Secure a water source
Established staging area for tools and equipment
[1602/Bomb]
Second arriving engine responsibilities for a bomb emergency
PD is in charge of the scene
Confirm bomb and arson squad has been activated
Hazmat
Crime scene
FBI/ATF
Determine size of device
500 feet for a pipe bomb
1000 feet for packages 1 to 25 pounds
1500 feet for cars and greater for larger vehicles
Multiple radio channels may be needed
[1602/Bomb]
Special considerations for a bomb emergency
Building collapse assignment: [1603/Collapse]
Multi company, battalion chief, TRT, code 3
Establish command
Look for signs of terrorism
Declare working fire if indicated
Secure a water source
Solicit information from facility staff
Initiate PAR
Begin recovery efforts
Update incoming battalion chief
Request hazmat, TRT or USAR as needed
[1603/Collapse]
First arriving engine responsibilities on a building collapse
Structure stability
Beginning in areas that are stable
Beginning area where the most victims are suspected
Broken or exposed utility services (Electric)
Heavy equipment may be needed for debris removal
[1603/Collapse]
Special considerations for a building collapse
Request gas company
Request hazmat
An equal number of backup personnel will be standing by (expanded RIC)
[1604/Natural gas leak]
Gas emergencies incidents management
Stop a minimum of 300 feet upwind
Advise dispatch and incoming units
Beware of the existence of static electricity in PVC
(Do not plug this leak)
Type of leak
If there is no fire, attempt to locate shut off valve and close only if it is for an individual service
[1604/Natural gas leak]
Gas emergencies response
Africanized bees assignment: [1701/Bees]
Two engines, rescue, battalion chief
On night operations, use of _______ may attract bees. The use of _______ _______ are acceptable. [1701/Bees]
Lights, red lights
_______ produced fire rescue and suppression vehicles or other heavy machinery may attract and/or aggravate agitated bees. [1701/Bees]
Vibrations
Avoid smashing bees on PPE as this will initiate the release of an _______ _______ . [1701/Bees]
Alarm pheromone
Hot zone 150 feet
Warm zone 300 feet
Cold zone over 300 feet
[1701/Bees]
Africanized honeybees control zones
_______ _______ _______ _______ solution will be the agent used for swarm/colony destruction. [1701/Bees]
3% Class A Foam
The Africanized honey bee colonies will continue to be highly defensive up to _______ _______ . [1701/Bees]
24 hours
The RAD-57 probe is not intended for use on patients under _______ . [1702/CO]
30 kg
Heavy smokers can have carboxyhemoglobin levels up to ________ . [1702/CO]
10%
For any event with more than _______ _______ involving possible CO exposure, the medical director or designee should be contacted. [1702/CO]
Five patients
Study chart [1702/CO]
Study chart [1702/CO]
Water moving at a rate greater than one knot. [1703/Dive team]
Swift water
There are _______ exercises that evaluate stamina and comfort level in the water. A maximum _______ minute interval between catch each exercise should be afforded each driver. If the dive team member does not successfully pass the skills evaluation, they will be given one re-evaluation within _______ months. [1703/Dive team]
4, 10, 2
For the purpose of this document, cold water shall be defined as water having a temperature below _______ °F [1703/Dive team]
70°F
Hydraulic elevators are hydraulic power instead of cables and traction sheaves and are generally limited to _______ story buildings. [1704/Elevators]
6 (per SOG [1704/Elevators])
The equipment rooms for hydraulic elevators are normally located at the lower level of a building, but can be at any floor level or _______ _______ _______ _______ away from the elevator shaft. [1704/Elevators]
50 to 100 feet
The equipment room for a _______ elevator is usually located above the hoistway. It contains the main power, electrical shut off for the elevator drive motor. This circuit could only be energized to _______ V. [1704/Elevators]
Traction, 600
You will find a _______ V shut off for the elevator. This shut off controls the lights and the fans within the elevator car. [1704/Elevators]
110
Review diagrams page 2. [1704/Elevators]
Review diagrams page 2
Elevator car emergency assignment: [1704/Elevators]
Engine, code 1
1) Size up
2) Determine if any medical needs are present
3) Confirm the elevator car "stop" button is not engaged
4) Secure power at main breaker
5)Report to floor where elevator is located
6) Attempt to reset the elevator by turning the main breaker off for 30 seconds
7) If unsuccessful, use fireman's service key
8) For normal operations, turn key to reset and then to the off position
[1704/Elevators]
Engine responsibilities on an elevator emergency
Review elevator emergency SOG [1704/Elevators]
Review elevator emergency SOG
ASHE [1705/ASHE]
Active shooter hostile event
Triage
Extraction
Treatment
Transportation
[1705/ASHE]
Key tactical positions in ASHE
Threat based care, triage and extracting victims to a casualty collection point. [1705/ASHE]
Rescue task force (RTF)
During ASHE, the initial responding battalion chief should contact Davie PD dispatch on _______ _______ . [1705/ASHE]
X-Ray 21
Fire rescue resources shall never operate within the _______ zone unless they have received special training (SRT). [1705/ASHE]
Hot (RTF is in the warm zone)
The most effective actions when firefighters find themselves in an unpredicted, possibly violence situation is (3) : [1705/ASHE]
Run, hide, fight
Essentially three things bring on excited delirium: [1706/Taser/excited delirium]
Overdose
Drug withdrawal
Psychiatric subject is off medication
Scene secure
Determine how many 5 second cycles of energy the individual has been exposed to
[1706/Taser/excited delirium]
Procedure for a patient that has been TASED
Fire personnel cannot remove the taser probes. If PD removes them, the probes can be stored in _______ _______ _______ . [1706/Taser/excited delirium]
The Taser cartridge
All active SRT tactical medics shall carry their _______ cell phone with them that is capable of receiving notification on a 24 hour call out basis. [1707/SRT]
Personal
The activation of the SRT team will be the result of either an _______ event (Hostage situation) or a _______ event (High risk warrant). [1707/SRT]
Unscheduled, scheduled
If a member of SRT is injured, an on duty staffed rescue unit and _______ _______ _______ _______ will accompany that member to the hospital. [1707/SRT]
One of the SRT tactical medics
Off duty SRT/training : SRT - Overtime
On duty SRT/training : SRT - Regular
Backfill OT SRT : SRT - Backfill
[1707/SRT]
Telestaff codes for SRT
Therapy dogs will be deployed as a supplement to the CISM following a request by the appropriate _______ _______ or _______ _______ . [1708/Therapy dog]
Battalion chief, assistant chief
Therapy dogs are available between the hours of _______ hours and _______ hours. [1708/Therapy dog]
0730, 2200
17220 Griffin Rd.
Southwest ranches, FL 33331
954-797-1162
[2000/Southwest ranches]
Station 112 address
Southwest ranches gates are located on:
SW 199th Ave
SW 202nd Ave
SW 205th Ave
[2000/Southwest ranches]
Location of Southwest Ranches gates
Weekly apparatus inventory at Southwest Ranches Station 112:
Saturday - _______
Sunday - _______
[2000/Southwest ranches]
R112, E-112
THIS SET IS OFTEN IN FOLDERS WITH...
Medical Protocols: Section 1
39 terms
Strategic and Tactical Considerations on the Fireg…
137 terms
Fire Officer Principles and Practices
13 terms
Department SOPs
81 terms
YOU MIGHT ALSO LIKE...
NYC FSD test
191 terms
NYC FSD test
191 terms
FSD NYC
406 terms
Hydro Mid-Term
156 terms
OTHER SETS BY THIS CREATOR
Emergency Response Guide
11 terms
Town Policies
26 terms
Incident Safety Officer
19 terms
CBA